![]() A barometric draft control can potentially lengthen and intensify any chimney fire by allowing an unlimited supply of combustion air. Note: When used with woodstoves, the connector pipe and flue must be inspected and kept clean. tee with black finish barometric draft control. (These findings must be kept in perspective, as woodstoves operated at extremely slow burn rates can still produce dangerous levels of creosote, even when operated with a barometric damper.)īoth coal and wood stoves will benefit from the installation of a barometric draft control.īlack 24g. Research has also linked the use of barometric dampers with substantial creosote reduction in the operation of woodstoves. ![]() The automatic stabilizing effect on the fire will generally lengthen the duration of burn and maintain a more constant heat output. Residential and CommercialThe Field RC is furnished as standard equipment on many. Raise the setting if there is not enough heat. But if plant overheats, change to a lower draft setting. Usually a draft of -.06' will be sufficient for cold weather, with reasonably quick pickup after a banked period. Close any check damper and open wide any internal damper. In cases of excessively strong draft, two barometric controls in series may be required. DetailsField Controls 46207201 5RC Barometric Draft Control, 5 inch. Adjust the draft control when a good fire is burning. Fire Rated - Edge Seals - UL10C - Positive Pressure. Intertek Testing (Warnock Hersey) Sound Tested - ASTM E90. The draft control can only decrease draft, it has no ability to increase draft. Category H - Gasketing - Smoke and draft control for positive pressure openings. They will do an excellent job of maintaining the draft setting within reasonably close tolerances except when the total draft in the chimney drops below the setting on the barometric draft control. As the flap opens (with greater draft), more air is let into the chimney, thereby decreasing the draft to the appliance.įield Barometric Draft Controls have adjustable weights which allow the units to be set for the particular draft required. A counterbalanced flap opens and shuts depending on the strength of the negative pressure (draft) in the chimney. It stabilizes the draft to any appliance located below the barometric draft control. Others seem to “hang up” at low draft settings, making them essentially inoperative. We’ve Examined A Lot Of Draft Controls, Some Cost More And Some Less, But The Field Barometric Draft Control Is The Best We’ve Found For Both Operation And Price.
0 Comments
Leave a Reply. |